Yokogawa UT35A Temperature Controller

Yokogawa UT35A Temperature Controller

Product Details:

  • Display Digital
  • Product Type Yokogawa UT35A Temperature Controller
  • Application Temperature controller
  • Warranty 1 Year
22000 INR/Unit
X

Price And Quantity

  • 22000 INR/Unit
  • 1 Unit

Product Specifications

  • Yokogawa UT35A Temperature Controller
  • Temperature controller
  • 1 Year
  • Digital

Trade Information

  • Cash Advance (CA)
  • 1 Days
  • All India

Product Description

Yokogawa UT35A Temperature Controller that we are offering is a precision device designed to control a heater or other equipment by comparing a sensor signal with a set point. Owing to its superior design and reliable performance, it is preferred by our customers. Yokogawa UT35A Temperature Controller is easy to install and maintain. It does not degrade in quality or become inferior in the long run. Our customers can approach us to purchase the controller at a budget-friendly price.

 Specifications :

Universal Input (Equipped as standard)

Number of inputs: 1

Input type, instrument range, and measurement accuracy: See the table below,

Input Type

Instrument Range

Accuracy


ºC

ºF


Thermocouple

K

-270.0 to 1370.0ºC

450.0 to 2500.0ºF

±0.1% of instrument range ±1 digit for 0°C or more

±0.2% of instrument range ±1 digit for less than 0°C

±2% of instrument range ±1 digit for less than -200.0°C of thermocouple
±1% of instrument range ±1 digit for less than -200.0°C of thermocouple

-270.0 to 1000.0ºC

-450.0 to 2300.0ºF

-200.0 to 500.0ºC

-200.0 to 1000.0ºF

J

-200.0 to 1200.0ºC

-300.0 to 2300.0ºF

T

-270.0 to 400.0ºC

-450.0 to 750.0ºF

0.0 to 400.0ºC

-200.0 to 750.0ºF

B

0.0 to 1800.0ºC

32 to 3300ºF

±0.15% of instrument range ±1 digit for 400°C or more
±5% of instrument range ±1 digit for less than 400°C

S

0.0 to 1700.0ºC

32 to 3100ºF

±0.15% of instrument range ±1 digit

R

0.0 to 1700.0ºC

32 to 3100ºF

N

-200.0 to 1300.0ºC

-300.0 to 2400.0ºF

±0.1% of instrument range ±1 digit
±0.25% of instrument range ±1 digit for less than 0°C

E

-270.0 to 1000.0ºC

-450.0 to 1800.0ºF

±0.1% of instrument range ±1 digit for 0°C or more

±0.2% of instrument range ±1 digit for less than 0°C

±1.5% of instrument range ±1 digit for less than -200.0°C of thermocouple E.

L

-200.0 to 900.0ºC

-300.0 to 1600.0ºF

U

-200.0 to 400.0ºC

-300.0 to 750.0ºF

0.0 to 400.0ºC

-200.0 to 1000.0ºF

W

0.0 to 2300.0ºC

32 to 4200ºF

±0.2% of instrument range ±1 digit (Note 2)

Platinel 2

0.0 to 1390.0ºC

32.0 to 2500.0ºF

±0.1% of instrument range ±1 digit

PR20-40

0.0 to 1900.0ºC

32 to 3400ºF

±0.5% of instrument range ±1 digit for 800°C or more
Accuracy is not guaranteed for less than 800°C.

W97Re3-W75Re25

0.0 to 2000.0ºC

32 to 3600ºF

±0.2% of instrument range ±1 digit

JPt100

-200.0 to 500.0ºC

-300.0 to 1000.0ºF

±0.1% of instrument range ±1 digit (Note 1)

-150.00 to 150.00ºC

-200.0 to 300.0ºF

±0.1% of instrument range ±1 digit

Pt100

-200.0 to 850.0ºC -

300.0 to 1560.0ºF

±0.1% of instrument range ±1 digit

(Note 1)

-200.0 to 500.0ºC

-300.0 to 1000.0ºF

-150.00 to 150.00ºC

-200.0 to 300.0ºF

±0.1% of instrument range ±1 digit

Standard signal

0.400 to 2.000 V

±0.1% of instrument range ±1 digit

1.000 to 5.000 V

4.00 to 20.00 mA

DC voltage/current

0.000 to 2.000 V

0.00 to 10.00 V

0.00 to 20.00 mA

-10.00 to 20.00 mV

0.0 to 100.0 mV

The accuracy is that in the standard operating conditions: 23±2°C, 55±10%RH, and power frequency at 50/60 Hz.

Note 1: ±0.3°C ±1 digit in the range between 0 and 100°C, ±0.5°C ±1 digit in the range between -100 and 200°C.

Note 2: W: W-5% Re/W-26% Re(Hoskins Mfg.Co.). ASTM E988

Contact Input Specifications:

  • Number of inputs: See the table of Model and Suffix Codes.
  • Input type: No-voltage contact input or transistor contact input
  • Input contact rating: 12 V DC, 10 mA or more
  • Use a contact with a minimum on-current of 1 mA or less.
  • ON/OFF detection:
  • No-voltage contact input:
  • Contact resistance of 1 kΩ or less is determined as "ON" and contact resistance of 50 kΩ or more as "OFF."
  • Transistor contact input:
  • Input voltage of 2 V or less is determined as "ON" and leakage current must not exceed 100 μA when "OFF."
  • Minimum status detection hold time: Control period +50 ms
  • Use: SP switch, operation mode switch, and event input

 

Analog Output Specifications :

  • Number of outputs:
  • Control output: 1
  • Cooling-side control output of Heating/cooling type (Retransmission output terminal): 1
  • Output type: Current output or voltage pulse output
  • Current output: 4 to 20 mA DC or 0 to 20 mA DC/load resistance of 600 Ω or less
  • Current output accuracy: ±0.1% of span (±5% of span for 1 mA or less)
  • The accuracy is that in the standard operating conditions: 23±2°C, 55±10%RH, and power frequency at 50/60 Hz.
  • Voltage pulse output:
  • Use: Time proportional output
  • On-voltage: 12 V or more/load resistance of 600 Ω or more
  • Off-voltage: 0.1 V DC or less
  • Time resolution: 10 ms or 0.1% of output, whichever is larger

 

Retransmission Output Specifications :

  • Number of outputs: Retransmission output; 1, shared with 15 V DC loop power supply or Cooling-side control output.
  • Current output: 4 to 20 mA DC or 0 to 20 mA DC/ load resistance of 600 Ω or less
  • Current output accuracy (conversion accuracy from PV display on the set scale): ±0.1% of span (±5% of span for 1 mA or less)
  • The accuracy is that in the standard operating conditions: 23±2°C, 55±10%RH, and power frequency at 50/60 Hz.
  • This is not conversion accuracy through input and output but the performance of transmission output itself.

 

15 V DC Loop Power Supply Specifications :

  • (Shared with retransmission output or Cooling-side control output.)
  • Power supply: 14.5 to 18.0 V DC
  • Maximum supply current: About 21 mA (with short-circuit current limiting circuit)

 

Step Response Time Specifications :

  • Within 1 s (63% of analog output response time when a step change of 10 to 90% of input span is applied)

 

Relay Contact Output Specifications :

  • Contact type and number of outputs:
  • Control output: contact point 1c; 1 point
  • Heating/cooling type: contact point 1a; 2 points for both heating and cooling sides
  • Alarm output: contact point 1a; 3 points (common is independent)
  • Contact rating:
  • Contact point 1c (control output): 250 V AC, 3 A or 30 V DC, 3A (resistance load)
  • Contact point 1a (control output): 240 V AC, 3A or 30 V DC, 3A (resistance load)
  • Contact point 1a (alarm output): 240 V AC, 1A or 30 V DC, 1 A (resistance load)
  • Use: Time proportional output, alarm output, FAIL output, etc.
  • Time resolution of control output: 10 ms or 0.1% of output, whichever is larger

 

Transistor Contact Output Specifications :

  • Number of outputs: See the table of Model and Suffix Codes.
  • Output type: Open collector (SINK current)
  • Output contact rating: Max. 24 V DC, 50 mA
  • Output time resolution: Min. 200 ms
  • Use: Alarm output, FAIL output, etc.

 

Position Proportional Output Specifications :

  • Position signal input:
  • Slide resistance: 100 Ω to 2.5 kΩ of total resistance
  • 100% side and slide line: with disconnection detection
  • 0% side: without disconnection detection
  • Current input: 4 to 20 mA (with disconnection detection)
  • Sampling period: 50 ms
  • Measurement resolution: 0.1% of input span
  • Position proportional relay output:
  • UT35A: contact point 1a; 2 points, 250 V AC, 3 A or 30 V DC, 3 A (resistance load)
  • UT32A: contact point 1a; 2 points, 240 V AC, 3 A or 30 V DC, 3 A (resistance load)
  • Note: This should always be used with a load of 10 mA or more.

 

Heater Break Alarm Specifications :

  • Number of inputs: 2
  • Number of outputs: 2 (transistor contact output)
  • Use: Measures the heater current using an external current transformer (CT) and generates a heater break alarm when the measured value is less than the break detection value.
  • Current transformer input resistance: About 9.4 Ω
  • Current transformer input range: 0.0 to 0.1 Arms (0.12 Arms or more cannot be applied.)
  • Heater current setting range: OFF, 0.1 to 300.0 Arms
  • Heater current measured value display range: 0.0 to 360.0 Arms
  • Note: The CT ratio can be set. CT ratio setting range: 1 to 3300
  • Recommended CT: CT from U.R.D., Ltd.
  • CTL-6-S-H: CT ratio 800, measurable current range: 0.1 to 80.0 Arms
  • CTL-12L-30: CT ratio 3000, measurable current range: 0.1 to 180.0 Arms
  • Heater current measurement period: 200 ms
  • Heater current measurement accuracy: ±5% of current transformer input range span ± 1digit (CT error is not included.)
  • Heater current detection resolution: Within 1/250 of current transformer input range span
  • Break detection On-time: Min. 0.2 second (for time proportional output)

 

24 V DC Loop Power Supply Specifications :

 

  • Use: Power is supplied to a 2-wire transmitter.
  • Power supply: 21.6 to 28.0 V DC
  • Rated current: 4 to 20 mA DC
  • Maximum supply current: About 30 mA (with short-circuit current limiting circuit.)