DC1040 Honeywell Temperature Controller that we are offering is popularly known among our customers owing to its capability of withstanding heat, moisture, abrasive chemicals, and tough conditions. The temperature controller is a high-end device designed for fluid processing applications. It is an advanced industrial machine. DC1040 Honeywell Temperature Controller is easy to install and maintain. It can be purchased from us at a reasonable price.
Technical Data :
PV Input | Type of Input | TC (K, J, R, S, B, E, N, T, W, PL II, U, L), RTD (Pt100 JPt100 JPt50) Linear (-10 10mV, 0 10mV, 0 20mV, 0 50mV, 10 50mV) |
Input Sampling Time | 500 ms | |
Input Resolution | 14 bit (each) | |
Indication | PV/SP Indication | 4-digit, 7 segment display |
Constant Value Storage System | Non-volatile memory (EEPROM) | |
Indication Accuracy | 0.5%FS | |
Control Mode | Proportional Band (P) | 0 200% (On/Off action at P=0) |
Integral Time (I) | 0 3600 sec (PD action at I=0) | |
Derivative Time (D) | 0 900 sec (PI action at D=0) | |
Output | Cycle Time | 0 150 sec (4 20mA 0, SSR 1, relay 10) |
Relay Output | Contact, SPST(DC1010)/SPDT(1020,1030,1040), 3A/240VAC | |
Voltage Output | Voltage Pulse, 20VDC/20mA | |
Linear Output | 4 20mA, 0 5V, 0 10V, 1 5V, 2 10V | |
Motor Control Output | Three Position Step Control (Time proportional motor control) | |
Others | 1 SSR, 3 SSR, 1 SCR, 3 SCR | |
Alarm | Channel | 3 channels (optional) |
Mode | 17 alarm mode available | |
Timer | Flicker alarm, continued alarm, on delay timer alarm | |
Aux. Output | Output Signal | SP, PV |
| Type of Output | 4 20mA, 0 20mA, 0 5V, 0 10V, 1 5V, 2 10V |
2nd | Type of Input | 4 20mA, 0 20mA, 0 5V, 0 10V, 1 5V, 2 10V |
Sampling Time | 500 ms | |
Program | Pattern/Segment | 2 pattern/ 8 segment (each) |
| Availability | Pattern link & repeat, program/segment end alarm |
Communication | Type of Communication | RS-232, RS-485 |
General Specifications | Rated Power Supply Voltage & Frequency | AC 90-240V, 50/60Hz or DC15-50V, 4VA |
Power Consumption | Max. 8VA | |
Storage Temperature | -25C 65C | |
Ambient Temperature | 0C 50 C | |
Ambient Humidity | 50 85% RH (no condensation) |
INPUT ACTUATIONS
TC | K | 0.0 200.0, 400.0, 600.0, 800.0, 1000, 1200 C | |
| J | 0.0 200.0, 400.0, 600.0, 800.0, 1000, 1200 C | |
| R | 0.0 1600, 1769 C | |
| S | 0.0 1600, 1769 C | |
| B | 0.0 1820 C | |
| E | 0.0 800, 1000 C | |
| N | 0.0 1200,1300 C | |
| T | 0.0 400.0, 200.0 C, 0.0 350.0 C | |
| W | 0.0 2000, 2320 C | |
| PL II | 0.0 1300, 1390 C | |
| U | -199.9 600.0, 200.0 C, 0.0 400.0 C | |
| L | 0.0 400.0, 800.0 C | |
RTD | Pt100 | -199.9 600.0, 400.0, 200.0 C, 0.0 200.0, 400.0, 600.0 C | |
| JPt100 | -199.9 600.0, 400.0, 200.0 C, 0.0 200.0, 400.0, 600.0 C | |
| JPt50 | -199.9 600.0, 400.0, 200.0 C, 0.0 200.0, 400.0, 600.0 C | |
Linear | AN1 | -10 10mV | |
AN2 | 0 10mV | | |
AN3 | 0 20mV | | |
AN4 | 0 50mV | 0 20mA, 0 1V, 0 5V, 0 10V | |
AN5 | 10 50mV | 4 20mA, 1 5V, 2 10V |